4.9 google rating
super pro awardHVAC awardBBB logoDaikin logo
Home
/
Blog
/
Plano TX 75025 Goodman 15.2 SEER2 AC Replacement with Oncor Incentive

Plano TX 75025 Goodman 15.2 SEER2 AC Replacement with Oncor Incentive

Plano TX 75025 HVAC replacement with 15.2 SEER2 Goodman A/C & 80% AFUE furnace. AHRI certified system + Oncor energy incentive. 3-year labor warranty.

Plano TX 75025 Goodman 15.2 SEER2 air conditioner and 80% AFUE gas furnace replacement installed by Greentech Engineering with Oncor energy incentive
Plano TX 75025 Goodman 15.2 SEER2 air conditioner and 80% AFUE gas furnace replacement installed by Greentech Engineering with Oncor energy incentive
Plano TX 75025 Goodman 15.2 SEER2 air conditioner and 80% AFUE gas furnace replacement installed by Greentech Engineering with Oncor energy incentive
No items found.

Goodman 15.2 SEER2 A/C + 80% AFUE Gas Furnace Upgrade with Oncor Incentive

πŸ“ Project Location: Plano, TX 75025
🏑 Home Type: Single-Family Residential
πŸ” Old System: Aging Trane straight cool + gas furnace (horizontal attic application)
⚑ New System: Goodman 15.2 SEER2 High-Efficiency Split A/C + 80% AFUE Gas Furnace
πŸ’° Bonus: Qualified for Oncor Energy Efficiency Incentive
πŸ›  Labor Warranty: 3 Years

Why This Plano 75025 Homeowner Replaced Their System

The homeowner in Plano 75025 contacted us after experiencing:

  • Reduced cooling capacity during peak Texas heat
  • Aging Trane system with declining efficiency
  • Rising summer utility bills
  • Concern about reliability before peak season

After performing a load evaluation and airflow inspection, we recommended a properly matched Goodman high-efficiency straight cool system delivering 15.2 SEER2 performance (AHRI certified) β€” optimized for Texas cooling demand while maintaining dependable gas heat for winter.

For Plano homeowners, where cooling dominates annual runtime, SEER2 performance is critical for long-term operating cost control.

Installed System Overview

Outdoor Unit – Goodman 24,000 BTU Split Air Conditioner

AHRI Certified 15.2 SEER2 Performance

Key Features:

  • Energy-efficient compressor
  • Copper tube / enhanced aluminum fin coil (5mm diameter)
  • Factory-installed filter drier
  • Pre-charged for 15 ft line set
  • 10-Year Limited Parts Warranty (with homeowner registration)

Why 15.2 SEER2 Matters in Plano, TX

Plano summers routinely exceed 95Β°F. Higher SEER2 systems:

  • Reduce peak energy consumption
  • Improve dehumidification
  • Lower strain on compressor
  • Decrease long-term utility cost

This system is AHRI certified at 15.2 SEER2, exceeding base federal minimum standards β€” improving efficiency without the premium cost of inverter systems.

Evaporator Coil – Daikin/Goodman 30,000 BTU Cased Horizontal Coil

Features:

  • Factory-installed TXV (Thermal Expansion Valve)
  • All-aluminum evaporator coil
  • Rust-resistant thermoplastic drain pan
  • Rifled aluminum tubing with corrugated fin design
  • 10-Year Limited Parts + Unit Replacement Warranty

Why TXV Is Important

The factory-installed TXV allows:

  • Precise refrigerant metering
  • Better efficiency across varying loads
  • Improved humidity control
  • Longer compressor life

For humid North Texas conditions, TXV-equipped systems outperform fixed orifice coils.

Gas Furnace – Goodman 60,000 BTU 80% AFUE Multi-Position (Horizontal)

Key Engineering Features:

  • Heavy-duty aluminized-steel tubular heat exchanger
  • Silicon Nitride Igniter
  • Multi-speed ECM blower motor
  • Self-diagnostic control board
  • 20-Year Limited Heat Exchanger Warranty
  • 10-Year Limited Parts Warranty

Why ECM Blower Motor Matters

The ECM blower provides:

  • Lower electrical consumption
  • Quiet operation
  • Continuous fan capability
  • Better airflow consistency

Even in single-stage furnaces, ECM motors dramatically improve comfort and energy efficiency.

Engineering-Driven Installation Process (Not β€œSwap-the-Box”)

At Greentech Engineering HVAC, installation quality determines long-term performance.

Scope of Work Included:

βœ” Old Trane system removed and properly refrigerant recovered
βœ” New gas sediment trap & Safe-T drain switch installed
βœ” New concrete condenser equipment pad
βœ” Drain line cleared with pressurized nitrogen
βœ” New trap, vent, insulation & modifications
βœ” RX-11 line set flush + dry nitrogen purge
βœ” 15% silver brazing by certified technician
βœ” Pressure tested at 250 PSI (minimum 15-minute hold)
βœ” Vacuumed below 500 microns before charging
βœ” System commissioned and performance tested

This process ensures:

  • No moisture contamination
  • No acid formation
  • No hidden leaks
  • Proper refrigerant charge
  • Maximum SEER performance realization

Most premature failures occur because contractors skip these steps.

We do not.

Oncor Energy Efficiency Incentive – Added Savings

This Plano 75025 homeowner qualified for an Oncor Energy Efficiency incentive.

As an approved Oncor Participating Service Provider, we:

  • Handle all paperwork
  • Ensure AHRI match compliance
  • Verify efficiency requirements
  • Submit documentation properly

The incentive reduced upfront cost while upgrading to 15.2 SEER2 efficiency.

For homeowners in Plano, Frisco, McKinney, Allen, and surrounding Collin County areas β€” incentives can significantly improve ROI.

Performance Benefits for Plano 75025 Homeowners

After Installation:

  • Lower monthly cooling bills
  • Improved airflow balance
  • Faster temperature pull-down
  • Quieter operation
  • Reliable winter heating
  • 3-Year Labor Warranty included

This is a properly engineered, code-compliant, and efficiency-optimized system β€” not a rushed replacement.

Frequently Asked Questions (FAQ)

1. Q:Is 15.2 SEER2 good for Plano, TX?

A:Yes. For straight cool systems, 15.2 SEER2 provides strong efficiency without excessive upfront inverter cost. It’s ideal for cost-conscious homeowners seeking performance upgrade.

2. Q:What does AHRI certification mean?

A:AHRI certification verifies that the matched condenser + coil combination delivers rated performance. Without proper match, you may not achieve advertised SEER2.

3. Q:Why is TXV important?

A:TXV meters refrigerant dynamically, improving efficiency, humidity control, and compressor protection.

4. Q:What happens if installation is done improperly?

A:Improper vacuum, contamination, or airflow issues can reduce lifespan by years and void manufacturer warranties.

5. Q:How do I qualify for Oncor incentives?

A:Your home must:

  • Have Oncor residential electric service
  • Install qualifying efficiency equipment
  • Use an approved contractor

We verify eligibility before installation.

Why Plano Homeowners Choose Greentech Engineering HVAC

βœ” Engineering-first approach
βœ” ACCA-compliant installation standards
βœ” Oncor Participating Service Provider
βœ” Daikin/Goodman product expertise
βœ” Detailed commissioning process
βœ” Transparent documentation

We focus on static pressure, airflow verification, refrigerant integrity, and proper system sizing β€” not just equipment replacement.

Serving Plano 75025 & Collin County

If you're in:

  • Plano
  • Frisco
  • Allen
  • McKinney
  • Little Elm
  • Carrollton

And considering HVAC replacement β€” especially before peak Texas summer β€” now is the time to evaluate efficiency upgrades and available incentives.

Author

Siwei (Lucas) Chen
CTO | Greentech Engineering Heating & Air Conditioning
B.S. Mechanical Engineering, Virginia Tech
ACCA Certified (Manual J, S, D)
NCI Certified – Air Balancing & Duct Optimization
Daikin Comfort Pro Contractor
Oncor Participating Service Provider

Serving Dallas–Fort Worth homeowners with engineering-driven HVAC solutions.

If you're a Plano 75025 homeowner evaluating HVAC replacement, contact Greentech Engineering HVAC for a proper load calculation, airflow analysis, and incentive qualification review.

Efficiency is not just about the equipment.
It’s about the engineering behind it.

‍